TECHNICAL SUPPORT
Our technical knowledge on use of the information below is
the result of extensive research and long experience :
Please contact us for an optimal resolution of the problem.
expansion joints for facades, walls and ceilings (finished face solution)
![]() |
![]() |
![]() |
![]() |
Material:
Aluminium side plates with flexible insert for exterior and interior use, weather resistant.
Aluminium side plates with cellular neoprene sealing strips to compensate for unevenness in the masonry.
Standard colour | grey |
Special colours on request (subject to min. quantitatives) |
|
Production length | 4 m |
Special Properties:
- Double protection against water is possible for double fixed insert in aluminium profile.
- Profile absorbs large movement (fold insert)
- Profile absorbs settlements (insert is sliding within the metal profiles)
- On request, the flexible insert is also available in one piece up to approx. 50 m max
Profile | Joint width max mm |
Total movement mm |
---|---|---|
FA 25/300 | 30 | 10 (± 5) |
FA 25/500 | 75 | 40 (± 20) |
FA 25/700 | 100 | 50 (± 25) |
FA 25/900 | 150 | 100 (± 50) |
FA 25/1300 | 200 | 120 (± 60) |
FA 25/1400 (double insert) |
250 | 180 (± 90) |
FA 25/1800 (double insert) |
350 | 200 (± 100) |
Corner versions
Profile | Joint width max mm |
Total movement mm |
---|---|---|
FAE 25/400 | 30 | 10 (± 5) |
FAE 25/600 | 75 | 40 (± 20) |
FAE 25/800 | 100 | 50 (± 25) |
FAE 25/1100 | 150 | 100 (± 50) |
FAE 25/1500 | 200 | 120 (± 60) |
FAE 25/1600 (double insert) |
250 | 180 (± 90) |
FAE 25/2200 (double insert) |
350 | 200 (± 100) |
![]() |
Insert of profile FA 25/500 and FAE 25/600 |
![]() |
Insert of profile FA 25/700 and FAE 25/800 |
![]() |
Insert of profile FA 25/900 and FAE 25/1100 |
![]() |
Insert of profile FA 25/1300 and FAE 25/1500 |
![]() |
Insert of profile FA 25/1400 and FAE 25/1600 |
![]() |
Insert of profile FA 25/1800 and FAE 25/2200 |
INSTALLATION INSTRUCTIONS
The surface on which side plates of aluminium profile will be placed must be smooth
and free from contamination, so that, the side plates, provided with neoprene cellular strips,
lie firmly on the base. Then profiles are aligned and fixed by screws and dowels (on both sides at distance of 30 cm).
If joints are on the inside of the building, it is sufficient to glue the profiles in place with
our special adhesive (Kleber).
Screws are not necessary.
Always leave a gap of approx. 5 mm at the butt joints of the aluminium profiles.
After installation a permanently flexible sealing compound should be applied
![]() |
to these gaps.
When flexible insert is longer than
8/10 m, it is necessary to fix this, to avoid sliding.