TECHNICAL SUPPORT

Our technical knowledge on use of the information below is
the result of extensive research and long experience :
Please contact us for an optimal resolution of the problem.

panel  MIGUBEST - FIRE BARRIER JOINTS
system to realize fire barrier device  (for joints over 5 cm)
capable to ensure fire resistance stand-alone

Fire behavior:

  • Non-combustible material: A1 class
    (international laws)

Special Properties:

  • Fireproof expanded free from organic binders, from asbestos, doesn’t develop fumes or poison gases in case of fire
  • Prevents fire spread through joints and offers high thermal and acoustic insulation properties
  • Waterproof
  • No capillary penetration
  • Resistant to saltness and oils
  • No swelling or dissolution in organic solvents
  • Specific load: 40 kg/m³


Terms of supply:

Stripes or panels with aluminium foil facing.
Production length 1 m

 

MIGUBEST panel has been tested upon italian and foreign criteria and is supplied with certification upon Italian law in force.



Thermal conductivity
at a medium temperature
at ºC
W/mk
0
0,037
50
0,040
100
0,053
150
0,063
200
0,074
250
0,087
300
0,105
350
0,125
400
0,150
450
0,180
Conductivity in the field of low temperatures at ºC
W/mk
-80
0,026
-60
0,029
-40
0,032
-20
0,035
Limit Temperature of usag: DIN 52271 - A 81 p. 6a e 6b
(thickness reduction of 5%) = 825 ºC
Vapor diffusion
resistance factore:
DIN 52615 = 7